Throttle servo adjustment:
Throw and direction is adjustable. To move the servo enable collective stick control. Motor off must be at -115%.
The motor off position is also used for failsafe. Please check this out without blades for the right function. Therfore do 2 tests, one will be to turn the TX off, the other one to disconnect the RX from the VBar. Take note that there may be 2 failsafe settings, one between TX and RX and one between RX and VBar using others than Spektrum sats directly connected. As we can only detect a missing or out of range signal at our inputs as precondition for our internal failsafe, it is your turn to set the failsafe between TX and RX to motor off position.
Gear settings:
Autorotation Bailout mode:
When this mode is active and a preset headspeed signal is higher than -90, the autorotation bailout is armed. This will give a quick soft spoolup switching back to a preset headspeed (more than 0 %), to do autorotation training. Switching to a valid preset from below -90 % will cause normal spoolup.