Governor basic settings
Governor Parameters | Min | Max |
---|---|---|
Gain | 0% | 100% |
Curr Headspeed | 0 RPM | 3000 RPM |
Requested Headspeed | 0 RPM | 3000 RPM |
Governor Output | -100% | 100% |
Adjust for nitros with a start value around 60. For electrics start with a low value, around 25. Too much gain will cause throttle pumping at normal flight, too less will cause unstable headspeed.
Shows the current measured headspeed.
The headspeed that is requested by the preset Channel from the transmitter. The governor will try to reach the requested headspeed when it is active. Note that the rerquest will follow the preset channel with some delay to protect headspeed jumps.
Shows the current output signal of the governor, that is send to the throttle servo or the ESC.
Governor Status | Used |
---|---|
Gov Active | The Governor is active. |
Magnet | Magnet is seen on the Input |
Full Throttle | Governor commands full throttle |
Minimum limit | The Output is at the throttle minimum |
Ramp Limit | The startup ramp limits the output |
Failsafe | Output is idle due to failsafe |
AR Bailout armed | The next runup will be quick |